Duro-Last, “World’s Best Roof” and Duro-Guard are registered marks owned by Duro-Last, Inc.
U
p
dated: 10/31
/
2013
DURO-GUARD
®
ISO HD
1 of 2 www.duro-last.com 800-248-0280
Figure 1. Duro-Guard ISO HD (Shown as Recover Board)
Description:
Duro-Guard
®
ISO HD is a ½ inch thick high density
polyisocyanurate insulation panel specifically
designed for use as a cover/recover board. It is
manufactured on-line using premium performance
coated glass facers.
R-value of 2.5 is significantly higher than roof
cover boards made of wood fiber or gypsum.
Lightweight (11 lbs. per 4 ft. x 8 ft. panel).
Easy to cut, handle and install.
Manufactured with a blowing agent that has
zero ozone depletion potential (ODP) and
virtually no global warming potential (GWP).
Recycled content > 8%.
Compressive Strength > 90 psi.
4 pcf density provides enhanced physical
properties.
Passes ASTM Resistance to Mold Test.
Refer to Table 1 for physical properties.
Recommended Uses:
Mechanically attached Duro-Last
®
roof
systems.
Adhered/Fully Bonded Duro-Last roof systems.
Duro-Bond
®
roof systems.
Metal retrofit roof systems.
Underwriters Laboratories, Inc. Classifications:
Refer to Duro-Last’s UL Listings
(TGFU.R10128) for assembly details.
Factory Mutual Approvals:
FM 4450, FM 4470.
Refer to FM Approval’s RoofNav for details on
FM Approved systems (www.roofnav.com).
Flat Panels:
Available size:
o 4 ft. x 8 ft.
o 4 ft. x 4 ft.
o Thicknesses: ½ inch.
Installation:
In steel deck applications, Duro-Guard ISO HD
can only be used as a cover board over
insulation or as recover board over an existing
roof. It may be placed directly on flute filler in a
metal roof retrofit application assuming the
flutes are completely filled.
Panels must be kept dry before, during and
after installation. Install only as much insulation
as can be covered the same day with
completed roofing.
The use of multiple layers of insulation with
joints staggered a minimum of 6 inches
between layers is recommended to eliminate
thermal bridging.
Abut panel edges together and stagger joints of
adjacent panels.
Boards must be neatly fitted to roof deck and
around penetrations with no gaps greater than
¼ inch.
Refer to the appropriate Duro-Last roof system
specification and detail drawings for deck
preparation and attachment requirements.
TABLE 1. PHYSICAL PROPERTIES – COVER BOARD
Compressive
Strength
ASTM D 1621 > 90 PSI
Dimensional
Stability
ASTM D 2126
< .5 % linear change
(7 days)
Water
Absorption
ASTM C 209 < 1% volume
Resistance to
Mold
ASTM D 3273 Passed
Service
Temperature
260° F (126° C) or less